Authors
Jácome Fernández, Juan CarlosIssue Date
2018-03-10Subjects
Holoscopy CameraPlenoptic Camera
Capturing 3D Content
Integral Imaging
MLA Variable Focal Length
Microlens Array
Plenoptic Camera Calibration
3D printing of Microlens
Metadata
Show full item recordAbstract
Integral imaging has recently re-emerged as an alternative to current 3D capturing systems, providing post-production refocusing capabilities and reducing the complexity of 3D capturing systems. One of the main drawbacks of conventional plenoptic 1 integral imaging systems is the implementation of a single custom made microlens array which has a fixed focal length and a high cost/low scalability associated with. This thesis demonstrates a variable focal length microlens arrays system, which can flexibly operate within a range of various focal lengths, increase the cost-effectiveness of the integral imaging system and offers the opportunity to manipulate the main camera optical parameters without modifying the objective lens settings. To validate the proposed concept, a custom-made integral imaging camera system was designed and built (IMPERX 4K system). Based on the results obtained from two initial optical simulations, software simulation and mathematical model; the suitable microlens arrays were acquired, and several experiments were performed to establish the feasibility of a variable focal length microlens arrays system. The results obtained show the proposed system performed as expected. The variable focal length system represents an ideal method to control microlens focal length, as it offers a higher microlens count, without a dedicated electronic system, whose performance is not susceptible to temperature-pressure changes and can operate in real-time as it does not require downtimes to re-adjust. Additionally, an existing technique of increasing the spatial resolution in Plenoptic 1 systems was conducted using a different implementation method. An alternative technique to fabricate microlens arrays using commercial 3D printers was attempted. Throughout the research, the quality of the images was improved using relevant optical elements and optimal optical integrations.Citation
Jácome Fernández, J.C. (2018) 'Capturing of 3D content using a single aperture camera'. PhD thesis. University of Bedfordshire.Publisher
University of BedfordshireType
Thesis or dissertationLanguage
enDescription
"A thesis submitted to the University of Bedfordshire, in partial fulfilment of the requirements for the degree of Doctor of Philosophy".Collections
The following license files are associated with this item:
- Creative Commons
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 International