Effect of ramp rate and reliability of peak physiological responses during arm crank ergometry
Authors
do Amaral, Ivan BrancoIssue Date
2005-08Subjects
asynchronous arm crank ergometryexercise testing
peak physiological responses
C600 Sports Science
Metadata
Show full item recordAbstract
Introduction: Asynchronous arm crank ergometry (ACE) is a viable mode of exercise testing for specific groups (e.g. wheelchair-bound individuals, kayakers) and is employed within clinical settings for the purpose of rehabilitation. This study aimed to; (1) investigate peak physiological responses to three ACE tests varied with respect to ramp rate, (2) from these to identify an optimal test based upon the attainment of vo2 peak. and (3) to assess the extent of test-retest reliability for each selected parameter. This was achieved by way of requiring individuals to repeat their optimal test. Methods: Eighteen healthy men performed three exercise tests, differentiated in ramp rate, in a random order. These consisted of a standard 4 min warm-up after which time the workload increased by 6 (T1), 10 (T2) or 12 W.min-1 (T3). An imposed crank rate of 80 rev.min-1 was maintained throughout all tests. The optimal test (Topt) for each subject was defined as that which elicited the highest value of oxygen consumption ( V02 peak). In order to assess test-retest reliability Topt was repeated. Systematic bias for all parameters between T1, T2 and T3 was assessed using separate one-way ANOVA tests with repeated measures. Reliability of the parameters was assessed using a number of conventional statistical procedures. Results: Peak power output (PPO) was significantly higher (P<0.05) with the 12 W·min-1 ramp test. Peak lactate (Hlapeak), peak respiratory exchange ratio (RERpeak) and PPO were significantly lower (P<0.05) in T1. There was no systematic change between test-retest (P>0.05) and all measures were within 10% variation as determined by 95% confidence intervals (95%CI). Conclusions: T2 and T3 are both equally appropriate for eliciting peak physiological responses in ACE while T3 is most appropriate for peak functional capacity. Traditional reliability measures suggested an appropriate level of test-retest reproducibility.Citation
do Amaral, I.B., (2005) 'Effect of ramp rate and reliability of peak physiological responses during arm crank ergometry'. Master of Science by Research thesis. University of Bedfordshire.Publisher
University of BedfordshireType
Thesis or dissertationLanguage
enCollections
The following license files are associated with this item:
- Creative Commons
Except where otherwise noted, this item's license is described as http://creativecommons.org/licenses/by-nc-nd/4.0/


