    GC/MS data reduction using retention time alignment and spectral subtraction

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Authors
    Hitchcock, Jonathan James
    Li, Dayou
    Maple, Carsten
    Keech, Malcolm
    Teale, Phil
    Hudson, Simon
    Affiliation
    University of Bedfordshire
    HFL Ltd
    Issue Date
    2007-09-10
    Subjects
    gas chromatography
    mass spectrometry
    retention time alignment
    anti-doping screening
    
    Metadata
    Show full item record
    Abstract
    The identification of chemical compounds in a complex mixture is a challenge. In the context of drug surveillance for the sporting world, large-scale screening of urine and blood samples is undertaken using methods such as GC/MS with low-resolution mass spectrometers that measure integer values of m/z ratio. The analysis of the GC/MS data can be automated using standard mass spectrometry software to detect peaks in the chromatograms and to search a library of mass spectra of known drugs. Because of noise and the presence of co-eluting compounds, the mass spectra are usually not exactly the same as those in the library. The match quality for a genuine match can be quite low, and the library search settings must be sufficiently sensitive so as not to miss positive samples. Therefore many false matches are reported for checking and validation by human analysts, and, since almost all the samples are negative, this process of checking is tedious, time-consuming and cost-inefficient. The usual technique to remove unwanted background is to subtract the spectrum of an adjacent scan of the same sample. Our proposed method instead subtracts the spectrum of a second similar sample. The intention is that any contributions from a substance common to the two samples will be eliminated, and that any substance that is in the first sample but not in the second will still be recorded in the subtracted dataset. Assuming a suitable second sample is available that does not contain banned substances, those that are present in the first sample can be more easily detected. The subtraction is applied to each scan of the test sample. For this to work, it is essential that retention times are precisely aligned so that a corresponding scan of the second sample can be chosen. Although many methods of alignment are described in the literature, simple linear alignment based on a correlation measure is found to be sufficient. It is also necessary to scale the spectra being subtracted to allow for differences between the two samples in the concentration of the common compounds. Subtracting a similar dataset will reduce the number of peaks to be considered, and our hypothesis is that a library search of the resulting dataset will produce a smaller number of false matches than the same library search applied to the original data. An experiment was carried out to test this and the number of false matches was indeed found to be reduced. The more similar the second sample was to the first, the better was the result. It was also verified that true matches of compounds of interest are still reported by the library search of the subtracted data.
    Citation
    Hitchcock, J., D. Li, C. Maple, M. Keech, P. Teale, and S. Hudson, 2007. “GC/MS data reduction using retention time alignment and spectral subtraction”, British Mass Spectrometry Society 29th Annual Meeting Book of Abstracts.
    Publisher
    British Mass Spectrometry Society
    URI
    http://hdl.handle.net/10547/297891
    Type
    Conference papers, meetings and proceedings
    Language
    en
    Collections
    Centre for Research in Distributed Technologies (CREDIT)

    entitlement

     
    DSpace software (copyright © 2002 - 2021)  DuraSpace
    Quick Guide | Contact Us
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.